Rotable Parts Exchange serves as a comprehensive source for military products, aerospace equipment, and Switch Pressure items. You have expressed particular interest in part number 9016GAW-1, a Schneider Electric Gmbh component we offer that is presented with the NSN 5930-01-287-0013 for straightforward identification and procurement. By completing and submitting the Request for Quote form provided on this page, you can obtain pricing details on this NSN part for your comparisons. Once our staff members receive and review your submitted information, a dedicated account manager will directly contact you with a response within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to streamline the purchasing process and simplify it as much as possible, which includes providing detailed listings for all components to help customers pinpoint their exact needs. For instance, part number 9016GAW-1 is manufactured by Schneider Electric Gmbh under the CAGE Code 56365. Additionally, by using the initial digits of the NSN 5930-01-287-0013, you can discover that this component is associated with the FSC 5930 Switches. If you have any specific questions about our database, you may always give us a call or email, as we would be delighted to assist you however we can. Otherwise, we encourage you to secure a quote for part number 9016GAW-1 at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-287-0013 Item PartTypeName: SWITCH,PRESSURE | 5930 | 012870013 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9016GAW-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE |
AXGY | MOUNTING METHOD | BRACKET |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,BOTH POSITIONS MAINTAINED |
CTHF | CONTACT LOAD CURRENT RATING | 1.2 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 1.5 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 100.0 MILLIAMPERES RESISTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 270.0 MILLIAMPERES RESISTIVE LOAD SIXTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 550.0 MILLIAMPERES RESISTIVE LOAD FIFTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 6.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYX | CONTACT STIMULUS RATING | -30.00 ACTUATION POINT MINIMUM INCHES OF MERCURY AND 0.00 ACTUATION POINT MAXIMUM INCHES OF MERCURY |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 600.0 AC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 600.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |