Rotable Parts Exchange serves as a comprehensive source for military products, aerospace equipment, and Circuitbreaker items. You have expressed particular interest in part number GT3-A3-DU0250-02A, a Heinemann Electric Co Inc component we offer that is presented with the NSN 5925-01-472-9844 for straightforward identification and procurement. By completing and submitting the Request for Quote form provided on this page, you can obtain pricing details on this NSN part for your comparisons. Once our staff members receive and review your submitted information, a dedicated account manager will directly contact you with a response within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to streamline the purchasing process and simplify it as much as possible, which includes providing detailed listings for all components to help customers pinpoint their exact needs. For instance, part number GT3-A3-DU0250-02A is manufactured by Heinemann Electric Co Inc under the CAGE Code L3330. Additionally, by using the initial digits of the NSN 5925-01-472-9844, you can discover that this component is associated with the FSC 5925 Circuit Breakers. If you have any specific questions about our database, you may always give us a call or email, as we would be delighted to assist you however we can. Otherwise, we encourage you to secure a quote for part number GT3-A3-DU0250-02A at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-472-9844 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014729844 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
GJ3-A3-DU0250-02A | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 18000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
AAQL | Body Style | |
CPLM | Maximum Continuous Load Current Rating Per Pole | 250.0 AMPERES AC ALL LOCATIONS |
AGAV | End Item Identification | 6110-01-463-4082 |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 95.000 MAXIMUM AT 125 PCT ALL LOCATIONS AND 13.000 MINIMUM AT 125 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 3 |